Gecko Alliance Group creating products! building relationships!
Working in partnership with spa manufacturers and offering off the shelf or customized solutions for their products, from drawing board to packaging, is what we do best!
We design, we multiply, we deliver solutions for spas and hot tubs and we’ve been doing it for more than 30 years.
Spa-Craft proudly distributes Gecko products throughout Australia & New Zealand.
Fault
|
Description
|
|
---|---|---|
FLO
|
Open Flow/Pressure switch
|
|
FLC
|
Closed Flow/Pressure switch
|
|
Err
|
Electronic software error
|
|
Prr
|
Failure with the temp sensor
|
|
HL
|
Failure with the Hi-Limit
|
|
FrE
|
Possible freeze condition
|
|
. . . (3 dots flashing)
|
FLO or FLC error
|
|
. . . (with red LED lit on PCB)
|
Hi-Limit sensor failure
|
|
0.0 / 32F
|
Temp sensor failure
|
|
H20
|
Low water level
|
|
BOO
|
Pump 1 Boost mode (P1 runs 45min high speed with ozone)
|
|
CLE, CF
|
Reminder, time to clean filters
|
|
SbY
|
Standby mode (spa will shut down for an hour)
|
|
LOC
|
Touchpad is locked
|
|
LocP
|
Touchpad is partially locked
|
|
LocF
|
Touchpad is fully locked
|
|
Fxx, Fdxx
|
Filter cycle duration in hours
|
|
Dxx, Fdxx, Fsxx
|
Filter cycle delay in hours
|
|
Pxx
|
Purge cycle duration in hours
|
|
Exx, Edxx
|
Economy cycle in hours
|
|
Orxx (2.5-9)
|
Beyond normal temp limit (Over range)
|
|
CAL
|
Calibration error
|
|
Edxx, Esxx
|
Economy cycle delay in hours
|
Fault
|
Description
|
|
---|---|---|
SPHr
|
A hardware error was detected in the controller
|
|
SPoT
|
The controller’s internal temperature is too hot
|
|
SPIn
|
The Input Voltage is too low
|
|
SPF1
|
Fuse #1 is blown
|
|
SPF2
|
Fuse #2 is blown
|
|
SPF3
|
Fuse #3 is blown
|
|
SPbr
|
Incorrect breaks size set
|
|
SPoH
|
Over heat (Water has reached 48c or 119F)
|
|
rHHr
|
A hardware error was detected in the in.therm (Heater)
|
|
rHnH
|
Heater is trying to heat, but no rise in temperature rise detected (Not heating)
|
|
rHnF
|
No flow detected
|
|
rHnC
|
Communication error between the controller and heater
|
|
rHHL
|
High limit circuit tripped
|
|
rHPr
|
Temperature probe Failure
|
|
rHID
|
Incorrect hardware model (IN.Therm)
|
|
P1Er
|
No detection of current change when turning on and off (Pump 1)
|
|
P2Er
|
No detection of current change when turning on and off (Pump 2)
|
|
P3Er
|
No detection of current change when turning on and off (Pump 3)
|
|
CPEr
|
No detection of current change when turning on and off (Circ Pump)
|
|
bLEr
|
No detection of current change when turning on and off (Blower)
|
|
FnErP
|
No detection of current change when turning on and off (Fan)
|
|
Sc
|
The system is scanning all outputs to learn the current draw of every accessory
|
|
ScEr
|
A scan error was detected (System learning error)
|
|
LL- -
|
Low level software setting
|
|
Ph-xP
|
Number of phases (Incoming power)
|
|
br- -
|
Breaker settings
|
Fault
|
Description
|
|
---|---|---|
rHId
|
No match between heater and pack models
|
|
nH
|
Trying to heat water but no heat increase detected
|
|
nF
|
No flow condition is detected
|
|
Hr
|
Hi-Limit circuit tripped (water has reached 50C or 122F)
|
|
OH
|
Overheat. (Water temp at 44.5C or 112.1F)
|
|
rHnC
|
Communication error- (Heater to controller)
|
|
Prr
|
Temperature sensor failed
|
|
AOH
|
Spa controller to hot
|
|
SPin
|
Input voltage too low
|
|
FLO
|
No Flow detected
|
|
FLC
|
Flow switch closed
|
|
F1
|
Fuse #1 blown
|
|
F2
|
Fuse #2 blown
|
|
F3
|
Fuse #3 blown
|
|
ScEr
|
Scan error detected (System learning error)
|
|
FrEr
|
Input power frequency 50/60hz out of range
|
|
Sc
|
System scanning (1st power up)
|
|
bL
|
No firmware into system
|
|
P9
|
Programming firmware into system
|
|
UP-Ld or UPL
|
No valid low level software uploaded
|
|
SP-OT
|
Temperature inside controller is too high
|
Fault
|
Description
|
|
---|---|---|
Hr or Hr2
|
Internal hardware error
|
|
Prr or Pr2
|
Temperature sensor failure
|
|
HL or HL2
|
Hi-limit (Water has reached 48c or 119F)
|
|
FLO or FL2
|
Flow error
|
|
UPL
|
No low level configuration software in system
|
|
AOH or AO2
|
Temperature in the spa pack is too hot
|
|
OH or OH2
|
Water over temperature (Water has reached 43c or106F)
|
|
Er1
|
Communication between master & slave doesn’t work
|
|
SLA
|
The pack on which the main keypad is connected is a SLAVE
|
|
LL- -
|
Unable to select the desired low level (when you confirm it goes back into the low level menu)
|
|
LLEr
|
The selected configuration is not a swim spa configuration and a SLAVE pack has been detected
|
|
Stby
|
Standby mode
|
|
OFF
|
30 Min all out puts off
|
|
FX or FF- -
|
Filter cycle frequency per day
|
|
FS- -
|
Filter cycle start time
|
|
Fdx- -or d-
|
Filter duration in hours
|
|
EP 0 or EP 1
|
Economy mode on/off
|
|
ES- -
|
Economy mode start time
|
|
ED- -:
|
Economy mode duration in hours
|
|
EE- -
|
Economy mode end time
|
|
Econ
|
Economy mode set
|
|
rLY
|
Stuck relay
|
Great savings on selected products, check-in often for updated lists.
Once submitted, your pool/spa details will be entered into our sizing calculator along with your local weather details provided by the “Bureau of Meteorology”. A personalise evaluation will be emailed to you within 1-2 business days by a Sensaheat product specialist.